Gas Chromatography

3000 Micro GC Gas Analyzer

3000 Micro GC Gas Analyzer

Model: 3000 Micro GC
Manufacturer: INFICON
  • Rapid analyze
  • Detection limit:  trace of substance( low ppm )
  • Dimension(HxWxD)(cm):  1,2 channel:  15 x 25 x 41, 8.2 kg
  • Dimension(HxWxD)(cm): 3,4 channel:  15,5 x 47,2 x 42, 12.2 kg
  • Dimension(HxWxD)(cm): Portable:  15,5 x 36,4 x 41,3, 16.6kg
  • Temperature operation:  0 - 50ºC
  • Carrier gas: hydrogen, helium, nitrogen, argon
  • Carrier gas pressure:  552 ± 14 kPa
  • Column temperature:  ambient+ 15 - 180ºC
  • Linear dynamic range: 106 ± 10%
  • Repeatability: 0.2 – 1.0%
Buy product
CMS5000 Monitoring System

CMS5000 Monitoring System

Model: CMS5000
Manufacturer: INFICON
  • Ideal for monitoring VOCs, air and water
  • Dimension(HxWxD)(cm):  43 x 83 x 26
  • Operation: Temperature:  0 - 50ºC   
  • Operation:  Relative Humidity: 5 – 95% ( non-condensing )
  • Carrier gas: argon 99.999%
  • Carrier gas pressure:  420 – 690 kPa
  • GC Column:  DB-1, 0.32 mm ID, 30 m, 4.0 μm
  • Heated zones: Valves:  60ºC; Column: 225ºC; Detector:  110ºC
  • Dynamic ranges: 3
  • Sensitivity:  0.5ppb benzene in water, s/n: 200: 1
  • Sensitivity:  0.5 ppb MTBE in water,s/n: 15: 1
  • Repeatability: <5% RSD at 1 ppb
  • Detection limit :  ppb to ppt
Buy product
Micro GC Fusion Gas Analyzer

Micro GC Fusion Gas Analyzer

Model: Micro GC Fusion
Manufacturer: INFICON
  • Rapid analysis, 1-3 minutes
  • Fast temperature ramping extends analytical capability ( up to C12 )
  • Dimension(HxWxD)(cm): 43.3x20x26.5
  • Environmental conditions: Temperature:  0 - 50ºC
  • Environmental conditions: Relatived humidity:  5 – 95%
  • Detector:  Mems TCD
  • Carrier gas: hydrogen, helium, nitrogen, argon
  • GC Column:  WCOT, PLOT
  • Detection limit:  1ppm
  • Linear dynamic range: 106 ± 10%
  • Repeatability: Retention time: ≤0.1% RSD
  • Repeatability: Peak Area:  ≤1%RSD
Buy product
Explorer Portable Gas Chromatograph

Explorer Portable Gas Chromatograph

Model: Explorer
Manufacturer: INFICON
  • Ideal for monitoring VOCs in environment
  • Connected PC – RS232
  • Dimension(HxWxD)(cm):  43 x 83 x 26
  • Operation: Temperature:  0 - 40ºC 
  • Operation: Relative Humidity: 5 – 95% ( non-condensing )
  • Carrier gas: UHP nitrogen gas
  • GC Column:  3
  • Temperature:  40 - 80ºC
  • Detector:  PID – Photoionization 10.6 eV UV lamp standard
  • Detection limit :  0.005 – 9999 ppm
  • Modes of operation: gas speciation or total VOC
Buy product